How To Clean Laminar Flow Hood

With each slice of lab equipment, there are unlike steps you demand to accept to ensure you take a sterile and safe surround. We will discuss how to effectively perform laminar flow hood cleaning and give you a few other tips to ensure your lab is safety.

Start Up The Unit

The first thing you will want to do is offset the unit. It is important to have the hood blowing for at to the lowest degree 30 minutes prior to first the cleaning process.

Suit Upwards And Become The Cleaning Equipment!

Earlier you brainstorm the cleaning process, you are going to desire to ensure you lot are wearing sterile clothing. Start by putting on the advisable PPE. This generally involves wearing a gown with gloves, a mask, head covering, and shoe coverings.

Lab technician in a full body gown and mask reviewing a checklist

During this stage you will also want to catch laboratory grade cleaning wipes along with a 70% ethanol spray solution. (Lather and water should not be used and ever use lint free cleanroom apparel)

Pre-Cleaning Of import Facts To Know

Before you lot brainstorm cleaning the unit, in that location are few important things you need to know.

HEPA Filters

HEPA filters are very fragile and require conscientious attention every bit to not be damage when cleaning the unit. Depending on how your unit is prepare up, you may have a metal shield over the HEPA filter which can be wiped downwardly. Do not employ excessive force per unit area when wiping this shield as you could harm the filter if as well much pressure is applied. You also should never spray cleaning solution directly on the shield, instead spray the solution onto a wipe.

illustrated drawing of air and contaminants passing through a HEPA filter

In other units, y'all may non accept a protective metallic shield in front end of the filter. Instead, information technology may be a metallic grate where you can easily see the filter media. In this style of hood, you should non clean the HEPA filter surface.

Wipes

You should use a make clean wipe for each surface of the hood. This reduces the hazard of contamination.

Start Cleaning

In the first phase of the cleaning process you will be using the laboratory grade cleaning wipes.

Start by cleaning the ceiling of the unit of measurement first for horizontal laminar flow hoods. (For vertical laminar period hoods yous volition skip this step unless your HEPA filter on the ceiling has a protective shield.) Offset in the back-left corner and make clean from left to correct with a long swiping motion. Equally you movement from dorsum to front, overlap each swipe by 25 to 50% to ensure all surfaces go cleaned.

Side by side make clean the dorsum wall if a HEPA shield is present. Work from top to bottom using the same swiping and overlapping y'all used on the ceiling of the unit. If a shield is not present, and then you practice not clean the HEPA surface.

Adjacent piece of work your style to the sides of the unit of measurement, start in the back corner. Clean from meridian to bottom and from back to front. Ensure y'all use a make clean wipe for each surface.

Finally, it is time to clean the work surface. In a similar fashion every bit the ceiling cleaning, work from the back corner and wipe from right to left. Ensure a 25 to l% overlap on each wipe and practise this until you reach the front of the unit.

Sterilize The Unit of measurement

You volition follow the same steps laid out in a higher place, this time using a lint gratis textile and your lxx% isopropyl alcohol solution. E'er spray the alcohol onto the cloth and never direct onto the surfaces. Ensure a clean portion of the fabric or new material entirely are used for each of the surfaces you wipe down. And that'south it!

Be sure to dispose of all discarded materials in a biohazard waste-handbasket. If the unit has a UV Sterilizer, this can also exist used to disinfect the hood.

Ofttimes Asked Questions

What Are The Unlike Classes Of Laminar Menstruation Hoods?

There are 3 dissimilar classes of laminar flow hoods.

  • Class I Laminar Flow Hoods – These hoods the simplest of the three classes. These hoods practice a proficient job of protecting the user and exterior environment but do not protect the work substances or cultures from contamination.
  • Form II Laminar Flow Hoods – These hoods are often used when hazardous material and fumes pose a risk to the user. These hoods likewise provide a sterile aseptic environs for the materials in the hood. Class Ii hoods are used in applications involving BSL-1, two, and iii materials.
  • Class Iii Laminar Menstruum Hoods – These offer the most protection. They provide the ultimate level of possible protection. These units are gas tight and are used in BSL-4 materials. This frequently includes pathogens and infectious substances.

What Laminar Flow Hood Services Does Balcon Perform?

  • Arrival Velocity Measurements
  • Down-Flow Velocity Measurements
  • HEPA Filter Integrity Testing
  • Non-Feasible Particle Counting
  • Microbial Air Testing
  • Microbial Surface Testing
  • Temperature and Humidity Uniformity
  • Smoke Pattern Testing
  • Alarm Calibration
  • Site Installation

Source: https://balcontab.com/blog/laminar-flow-hood-cleaning/